Liebert Ups Models
liebert ups models
















  1. #Liebert Ups Models Series Is A#
  2. #Liebert Ups Models Full Spectrum Of#
liebert ups models

Liebert Ups Models Full Spectrum Of

A true double conversion UPS is the only way to guard against the full spectrum of power disturbances. See the productsconversion UPS products including line-interactive and others that call themselves on-line. This approach allows for right-sizing of the UPS, resulting in improved energy efficiency and reduced power expenditures.Discover our wide range of UPS systems, designed to cover the needs of your critical facility and ensure secure, uninterrupted power. The Liebert APM UPS scales from 15 to 45kW in a cabinet configuration that includes internal batteries, or from 15 to 90kW in 15kW increments in a configuration that reserves a cabinet for capacity that is paired with an external battery cabinet. When power requirements change, capacity is easily added – without increasing the system footprint.

Liebert Ups Models Series Is A

We can provide the appropriate battery from our large new battery inventory or source any brand battery you prefer. Categories: DPG Models, UPS.Liebert APM 60K-F 60kVA / 60 kW 208 volt UPS System in stock with a Maintenance bypass / power distribution cabinets and two matching battery cabinets. The Liebert Series 610 UPS includes a redesigned operator interface controlLiebert GXT RT+ DX series is a full featured transformer free scalable UPS designed to offer compact, efficient and reliable.

We supply brand new, factory fresh.Liebert APM 60K-F 60kVA / 60 kW 208 volt UPS System Bypass Distribution Cabinet External maintenance bypass provides complete serviceability while load is running on bypass utility power Integral distribution saves space and cost Kirk-key interlock ensures proper operation 65 kAIC rating meets high electrical withstand requirements.THIS UPS SYSTEM CAN BE CONFIGURED UP TO 90 kVA / 90 kW. 1.1 FeaturesThe replacement battery set for Emerson-Liebert GXT4 288V UPS unit is guaranteed to meet or exceed OEM specifications. This section describes the UPS, its features, models, appearance and components, operating principles and operating mode. The Liebert GXT3 continuously charges its batteries from the mains, enabling it to supply power to connected loads, even when the mains fail.

Voltage Range- +15%, -20% of nominal without derating Voltage Configuration for Standard Unit- 208V, three-phase, four-wire plus ground Battery systems are sold separately. All pricing includes the bypass / distribution cabinet. The 90 kVA / 90 kW configuration for the UPS would be $32,000.00.

Current Distortion- <3% reflected THD maximum at full load Current Limit- 140% of nominal AC input current maximum Maintenance bypass and distribution cabinet inrush current not to exceed 8 times rated input current. Inrush Current- UPS inrush current not to exceed 1.5 times rated input current.

Frequency Slew Rate- Selectable from 0.1Hz/sec to 3.0Hz/sec maximum for single unit Frequency- ☐.1% (single Liebert FlexPower assembly), ☐.25% (six Liebert FlexPower assemblies) Voltage Configuration- three-phase, 4-wire plus ground-☑% three-phase RMS average for a balanced three-phase load for the combined variation effects of input voltage, connected load, battery voltage, ambient temperature and load power factor-±5% three-phase RMS average for a 100% unbalanced load for the combined variation effects of input voltage, connected load, battery voltage, ambient temperature and load power factor

Output Power Rating- 99 full load. Load Power Factor Range- 7 lagging to 0.9 leading without derating Voltage Distortion- <1% total harmonic distortion (THD) for linear loads, <5% THD for 100% nonlinear loads (3:1 crest factor) without kVA/kW derating

Storage/Transport Ambient Temperature- UPS Module: -4☏ to 158☏ (-20☌ to 70☌), Battery: -4☏ to 86☏ (-20☌ to 30☌) Operating Ambient Temperature- UPS Module: 32☏ to 104☏ (0☌ to 40☌), Battery: 77☏ ☙☏ (25☌ ±5☌) Voltage Unbalance- 100% unbalanced load, ±5% Transient Recovery Time- to within 5% of steady state output voltage within half a cycle Voltage Transient Response- 100% load step, ±5.0%